Applicable Industries:
- Hetronic Remote Control Parts
- Hetronic Bms Control Manual Pdf
- Hetronics Troubleshooting Remote
- Hetronic Bms Control Manual 2016
- Hetronic Bms Control Manual Pdf
We use cookies to ensure that we give you the best experience on our website. You may read about this on our Privacy & Site Policy page. User Manual Release Date; WFA1 User Manual 18900 06 Users Guide Rev01x: 2019-10-01: ERGOS2G4 User Manual User Manual: 2019-08-15: MFSERGO120 Users Manual Users Manual. Review control functions and operation of the machine and this radio remote control system. THEORY OF OPERATION The BMS System includes a transmitter and a receiver. The transmitter generates the electronic signal that com mun iates with the rev. IMT do ote control systems operate in the 400-470 MHZ range (70 cm band).
Concrete Pump Industry, Precast Industry, Crane Industry & Locomotives.
Nova L Series | Nova M Series | Nova S Series | Nova XL Series |
Nova L Series
Functions:
- Multiple axis joysticks with and without detent
- Momentary pushbutton for START/HORN
- 3-position maintained toggle switch
- 3-position maintained-off-momentary toggle switch
- Push mushroom head STOP switch
- 12 position rotary switch
- Key switch with removable key cap
Frequencies:
419 MHz, 429 MHz, 434 MHz, 447 MHz,458 MHz, 868 MHz
419 MHz, 429 MHz, 434 MHz, 447 MHz,458 MHz, 868 MHz
Autodesk 3ds max 9 activation code keygen. Power Supply:
3 LR6 Size AA 1.5 V Alkaline batteries or 3.6 V NiMH rechargeable battery
3 LR6 Size AA 1.5 V Alkaline batteries or 3.6 V NiMH rechargeable battery
Operting Range:
Upto 100m
Upto 100m
For sales Catalogue Download : Nova L Series Sales Catalogue
For Technical catalogue Download : Nova L Series Technical catalogue
Nova M Series
Functions:
- Multiple axis joysticks with and without detent
- Momentary pushbutton for START/HORN
- 3-position maintained toggle switch
- 3-position maintained-off-momentary toggle switch
- Push mushroom head STOP switch
- 12 position rotary switch
- Key switch with removable key cap
Frequencies:
419 MHz, 429 MHz, 434 MHz, 447 MHz,458 MHz, 868 MHz
419 MHz, 429 MHz, 434 MHz, 447 MHz,458 MHz, 868 MHz
Power Supply:
3 LR6 Size AA 1.5 V Alkaline batteries or 3.6 V NiMH rechargeable battery
3 LR6 Size AA 1.5 V Alkaline batteries or 3.6 V NiMH rechargeable battery
Operting Range:
Upto 100m
Upto 100m
For sales Catalogue Download : Nova M Series Sales Catalogue
For Technical catalogue Download : Nova M Series Technical catalogue
Nova S Series
Functions:
- Momentary pushbutton for START/HORN
- 3-position maintained toggle switch
- 3-position maintained-off-momentary toggle switch
- Push mushroom head STOP switch
- 12 position rotary switch
- Key switch with removable key cap
Frequencies:
419 MHz, 429 MHz, 434 MHz, 447 MHz,458 MHz, 868 MHz
419 MHz, 429 MHz, 434 MHz, 447 MHz,458 MHz, 868 MHz
Power Supply:
3 LR6 Size AA 1.5 V Alkaline batteries or 3.6 V NiMH rechargeable battery
3 LR6 Size AA 1.5 V Alkaline batteries or 3.6 V NiMH rechargeable battery
Operting Range:
Upto 100m
Upto 100m
Hetronic Remote Control Parts
For sales Catalogue Download : Nova S Series Sales Catalogue
Hetronic Bms Control Manual Pdf
For Technical catalogue Download : Nova S Series Technical catalogue
Nova XL Series
Functions:
- Single and Dual Axis Joysticks.
- Single Axis paddle levers
- Any combination of key switches, toggle switches, push buttons, rotary switches and stop switch.
- Customized switches availabe upon request
- Half and full duplex feedback
- cable back-up
Hetronics Troubleshooting Remote
Frequencies:
419 MHz, 429 MHz, 434 MHz, 447 MHz,458 MHz, 868 MHz & 1216 MHz
419 MHz, 429 MHz, 434 MHz, 447 MHz,458 MHz, 868 MHz & 1216 MHz
Power Supply:
3 LR6 Size AA 1.5 V Alkaline batteries or 3.6 V NiMH rechargeable battery
3 LR6 Size AA 1.5 V Alkaline batteries or 3.6 V NiMH rechargeable battery
Hetronic Bms Control Manual 2016
Operting Range:
Upto 100m
Upto 100m
For sales Catalogue Download : Nova XL Series Sales Catalogue
For Technical catalogue Download : Nova XL Series Technical catalogue
Hetronic Bms Control Manual Pdf
Manitowoc Boom Trucks
Radio Remote Controls - BMS GA610 For C & S Series Cranes
•Operator Manual
Manitowoc Boom Trucks, Inc. 3000 S. Austin Ave Georgetown, TX 78627-1609 Sales:
(512) 942-3000
Sales Fax:
(512) 863-3776
Service:
(512) 942-3000
Service Fax:
(512) 942-3094
Web Site: www.manitowocbt.com
Hetronic C & S Series
A
Company
February 2002
Operating Manual For Radio Remote Controls On Crane Systems
System GA 610
⊂∈ Please place serial number here ! Please keep for future reference ! Date of Issue: HETRONIC Steuersysteme GmbHé Adalbert-Stifter-Straße 2 é D-84085 LangquaidTel.: +49-(0)9452/189-0 Fax.: +49-(0)9452/189-20
Table of Contents 1.
Safety Requirement 1.1. Safety 1.1.1. 1.1.2. 1.1.3. 1.1.4. 1.1.5. 1.1.6. 1.1.7.
2.
Safety of the Radio Remote Control System Safety Information Possible Sources of Danger Authorised Operators Safety Measures to be Taken in the Work Area Protective Features Reaction in Emergency Situations
Operating Instructions 2.1. Battery Handling 2.1.1. 2.1.2. 2.1.3. 2.1.4. 2.1.5.
Inserting the Battery Changing the Battery Charging the Battery The Battery Charger Indication for the Battery Charger’s Installation
2.2. To Begin Operation 2.2.1. Optical Check – Up 2.2.2. Safety Check – Up and Starting the Radio Remote Control
2.3. Speed Control 2.4. Proportional Functions 2.5. Optical Displays and Acoustic Signals 2.5.1. Transmitter 2.5.2. Receiver
2.6. Frequencies and Addresses
3.
Warranty Validity
4.
Disposal
5.
Technical Specifications
6.
Exhibit A
1. Safety Requirement 1.1. Safety 1.1.1.
Safety of the Radio Remote Control System
This radio remote control system is equipped with electronic and mechanical safety features. Processing of control signals transmitted from other transmitters is not possible, since transmission coding is set only once. Risks can occur from improper operation or use, and these may include: -
Personal injury or death of the operator or other persons. Damage to the machine, other equipment or material assets.
All operators of this equipment must be qualified, trained and must follow precisely the operating instructions of this manual.
1.1.2.
Safety Information
The following notes are used in this manual:
WARNING!
This warns of the imminent danger of life threatening accidents and serious injuries which may result if operating instructions are ignored or disobeyed.
ATTENTION!
This warns of possible damage to the machine which may result if operating instructions are ignored or disobeyed (which can also result in loss of any warranty).
IMPORTANT!
This draws attention to features or information which will allow for easier operation.
1.1.3.
Possible Sources of Danger
This System makes remote control via radio signals possible. The transmission of control commands, however, can take place around obstacles and out of direct sight of operators. Therefore: 1.
2. 3.
1.1.4.
Switch 'off!' the transmitter and remove the key if the unit is placed any distance away from the operator. The key has to be switched 'off' (to the '0' position). Disconnect the power supply before any assembly, maintenance or repair work is done. Never remove or in any way alter any of the safety features of this system.
Authorised Operators
Always review the operating manual of any machine to be controlled by radio remote control! The key must be removed from the transmitter when the transmitter is placed any distance away from the operator in order to reduce the potential for unauthorised operation. The operating authority, owner or management must make the manual accessible for the operator and has to ensure that the operator has carefully read and fully understood each section of this manual.
1.1.5.
Safety Measures to be Taken in the Work Area
The operator must ensure that the work area in which the radio remote control unit will be operated is free from trip - hazards or other potential safety hazards (i.e. ensure work area is a 'non - slip' area). Operate the transmitter only with the accompanying carrying belt.
1.1.6.
Protective Features
The machine functions can be stopped either by: 1.
Pushing the emergency stop button on the transmitter control panel (EMERGENCY STOP!).
2.
Turning the transmitter key switch to the 'off' position (machine function will stop approximately 0.5 seconds (450 ms) after the switch is turned to the 'off' position).
Additional safety features include the protective guard around the upper section of the transmitter housing. This guard helps to protect against accidental activation of controls and unintentional operation. These safety features are included for the operator’s as well as other person’s protection within the work area.
WARNING!
1.1.7.
Safety features must not be removed or modified in any way.
Reaction in Emergency Situations
1.
If there is an emergency, press immediately the red emergency stop (EMERGENCY STOP!) push - button (see picture).
2.
After the emergency stop push - button has been pressed, follow carefully the instructions in the machine's operating manual.
Type GL
Type Nova 6
EMERGENCY – STOP – PUSH - BUTTON
2. Operating Instructions WARNING!
Operators are strictly forbidden to use the radio remote control unit unless they have carefully read and fully understood this operating manual. Special attention must be given to the safety instructions in this manual!
2.1. Battery Handling Each HETRONIC radio remote control system will be delivered with two fully charged batteries. One of them will be inserted into the battery compartment located on the bottom of the transmitter. The operating time of one charged battery is approximately 8 hours.
2.1.1. Inserting the Battery Ensure that the battery compartment is completely clean, as dirt might cause contact problems. Insert the battery with both guide pins in the corresponding guide bars of the battery compartment. Now press the battery on the marked spot until it latches into its compartment. Type Nova: Insert the battery with both guide bars on the lower side of the battery in the corresponding guide slots of the battery compartment. Now press the battery until it latches into its compartment.
Type GL
Type Nova
2.1.2.
Changing the Battery
The battery voltage will be controlled continuously by the transmitter’s electronic. An acoustic interval signal will be heard in the transmitter when the capacity of the transmitter battery is nearly exhausted. When the signal is heard the following steps must be immediately taken: -
Position the machine into a safe place or safe condition within 30 seconds after hearing the signal.
WARNING! -
The transmitter will switch to the Emergency Stop condition after 30 seconds!
Switch the transmitter 'off' by turning the key switch to the '0' position. Remove the discharged battery by pushing it slightly forward and lifting it up and out of the battery compartment. Insert a fully charged battery. Continue like described in point 2.2.2.'starting the radio remote control'. The radio remote control is again ready for operation.
Battery – type GL
Battery – type Nova
2.1.3.
Charging the Battery
WARNING!
Danger of Explosion! Use only HETRONIC original parts. If no original HETRONIC parts are used there could be a danger of explosion! An explosion may result in the release of harmful gases or fumes and / or flying debris. This may result in injury or death of the operator or others present within the work area.
Your HETRONIC radio remote control system will be delivered with fully charged batteries, that means your radio remote control system is immediately ready for operation. Battery Charging Instructions: Type GL: Insert the battery with both guide pins in the corresponding guide bars in the battery compartment of the battery charger. Type Nova: Place the battery with both guide bars on the lower side of the battery in the corresponding grooves of the battery charger’s battery compartment. Now press the battery on the marked spot until it latches into its compartment. The green LED on the charger stays lit during the charging process. When the battery is fully charged, the LED starts flashing. Insert the second battery into the battery charger to ensure that there is always a fully charged battery available.
2.1.4.
The Battery Charger
The battery charger operates with an operating voltage of 12 VDC / 24 VDC. A green LED indicates the beginning of the charging process. After a charging time of approximately 3,5 hours (type Nova), 6 hours (type GL) the flashing green LED indicates that the charging process is finished. The charger recognises automatically when the battery is fully charged. When it is fully charged, the charger switches to a 'trickle' charging condition. It does not matter whether the battery is discharged or partially charged, as the battery charger automatically regulates the charging process. To reach a long operating time of the batteries, you should charge the battery only when an acoustic interval signal is heard from the transmitter, which indicates that the capacity of the transmitter is nearly exhausted.
IMPORTANT!
Rechargeable accumulators are hazardous waste! Contact an expert company for the waste disposal and exploitation. Defective accumulators can be disposed by HETRONIC.
2.1.5.
Indication for the Battery Charger’s Installation
The charging unit should be installed in the vehicle and connected directly to the battery via a fuse. This means that it should also be operational when the ignition is switched off. The charging unit’s current consumption is so slight that effects on the vehicle’s battery are minimal. The system is protected against polarity reversal. Ensure that the charging unit will be operated on dry places only.
2.2. To Begin Operation The safety check as described in the following paragraphs 2.2.1. and 2.2.2. has to be completed before the radio remote control system is activated. The safety check must be performed at least once a day, before the start of any operation and at all shift changes.
IMPORTANT! A transmitter drawing is enclosed to this operating manual. Transmitter layout and inscription vary according to the customer’s requests. In most cases, however, they are identical to the inscription of the present control. The only difference is that the machine is controlled without a cable control. Consult the machine manufacturer’s manual and the transmitter drawing additional to inform about the arrangement of the transmitter’s operating elements and their corresponding functions. The following description refers to the control elements and peculiarities of the radio remote control.
WARNING!
2.2.1.
Danger to personnel and property! The operator must read and fully understand the emergency stop function outlined in the machine manufacturer's operating manual before beginning any operation! Test the EMERGENCY STOP function as described in the machine manufacturer's operating manual before beginning any operation!
Optical Check-up
Always check the transmitter for any physical damages before any operation. -
Do all safety features exist and are they in a good condition? No broken parts anywhere? All rubber cuffs and push button caps without rips?
Never operate a transmitter which has such damages! Eliminate the faults immediately!
2.2.2.
Safety Check-Up and Starting the Radio Remote Control
Check list for the first start of operation (this checklist must be carefully followed before beginning any operation!) -
-
-
-
WARNING!
Keyswitch on the transmitter in position '0' (off), emergency stop push - button in position '0' (off), (pull it out – type GL), (turn it right – type Nova). Insert a charged battery into the battery compartment located on the bottom of the transmitter (see section 2.1.1.). Switch the transmitter on by turning the keyswitch to the position 'I' (on) and a short acoustic signal will be heard. Wait for the second acoustic signal (approx. 3 seconds). The LED on the transmitters control panel will begin to flash. Now push the green push button “S1” on the transmitter. Check the deflection of the control elements. Do the machine functions correspond with the transmitter functions? Now check the EMERGENCY STOP function as described in the machine manufacturer’s manual. However use the EMERGENCY STOP push - button on the transmitter instead of the EMERGENCY STOP switch on the machine. Push the EMERGENCY STOP now. Make sure that no function can be controlled after pushing the EMERGENCY STOP push - button. Is the safety check successful and the EMERGENCY STOP function operates perfectly? Pull out the EMERGENCY STOP push - button. Push the green push - button 'S1' (start) on the transmitter. Both the radio remote control and the machine are now ready for operation.
Switch the machine 'off' immediately should there be a fault or any problems with the safety check. Inform your dealer at once to repair the system. Never operate a machine when the EMERGENCY STOP function does not operate properly. Danger to personnel and property by non - observance of this regulation. All measures which do not confirm with this regulation can lead to the loss of the operating permission and your warranty.
Starter – Push – Button “S1” Type GL
Type Nova
2.3. Speed Control The Radio Remote Control System BMS is equipped with a twofold speed control. It is possible to select a speed range via a switch. You can choose between a maximum adjustable power with switch position “rabbit” and a lower one with
Radio Remote Controls - BMS GA610 For C & S Series Cranes
•Operator Manual
Manitowoc Boom Trucks, Inc. 3000 S. Austin Ave Georgetown, TX 78627-1609 Sales:
(512) 942-3000
Sales Fax:
(512) 863-3776
Service:
(512) 942-3000
Service Fax:
(512) 942-3094
Web Site: www.manitowocbt.com
Hetronic C & S Series
A
Company
February 2002
Operating Manual For Radio Remote Controls On Crane Systems
System GA 610
⊂∈ Please place serial number here ! Please keep for future reference ! Date of Issue: HETRONIC Steuersysteme GmbHé Adalbert-Stifter-Straße 2 é D-84085 LangquaidTel.: +49-(0)9452/189-0 Fax.: +49-(0)9452/189-20
Table of Contents 1.
Safety Requirement 1.1. Safety 1.1.1. 1.1.2. 1.1.3. 1.1.4. 1.1.5. 1.1.6. 1.1.7.
2.
Safety of the Radio Remote Control System Safety Information Possible Sources of Danger Authorised Operators Safety Measures to be Taken in the Work Area Protective Features Reaction in Emergency Situations
Operating Instructions 2.1. Battery Handling 2.1.1. 2.1.2. 2.1.3. 2.1.4. 2.1.5.
Inserting the Battery Changing the Battery Charging the Battery The Battery Charger Indication for the Battery Charger’s Installation
2.2. To Begin Operation 2.2.1. Optical Check – Up 2.2.2. Safety Check – Up and Starting the Radio Remote Control
2.3. Speed Control 2.4. Proportional Functions 2.5. Optical Displays and Acoustic Signals 2.5.1. Transmitter 2.5.2. Receiver
2.6. Frequencies and Addresses
3.
Warranty Validity
4.
Disposal
5.
Technical Specifications
6.
Exhibit A
1. Safety Requirement 1.1. Safety 1.1.1.
Safety of the Radio Remote Control System
This radio remote control system is equipped with electronic and mechanical safety features. Processing of control signals transmitted from other transmitters is not possible, since transmission coding is set only once. Risks can occur from improper operation or use, and these may include: -
Personal injury or death of the operator or other persons. Damage to the machine, other equipment or material assets.
All operators of this equipment must be qualified, trained and must follow precisely the operating instructions of this manual.
1.1.2.
Safety Information
The following notes are used in this manual:
WARNING!
This warns of the imminent danger of life threatening accidents and serious injuries which may result if operating instructions are ignored or disobeyed.
ATTENTION!
This warns of possible damage to the machine which may result if operating instructions are ignored or disobeyed (which can also result in loss of any warranty).
IMPORTANT!
This draws attention to features or information which will allow for easier operation.
1.1.3.
Possible Sources of Danger
This System makes remote control via radio signals possible. The transmission of control commands, however, can take place around obstacles and out of direct sight of operators. Therefore: 1.
2. 3.
1.1.4.
Switch 'off!' the transmitter and remove the key if the unit is placed any distance away from the operator. The key has to be switched 'off' (to the '0' position). Disconnect the power supply before any assembly, maintenance or repair work is done. Never remove or in any way alter any of the safety features of this system.
Authorised Operators
Always review the operating manual of any machine to be controlled by radio remote control! The key must be removed from the transmitter when the transmitter is placed any distance away from the operator in order to reduce the potential for unauthorised operation. The operating authority, owner or management must make the manual accessible for the operator and has to ensure that the operator has carefully read and fully understood each section of this manual.
1.1.5.
Safety Measures to be Taken in the Work Area
The operator must ensure that the work area in which the radio remote control unit will be operated is free from trip - hazards or other potential safety hazards (i.e. ensure work area is a 'non - slip' area). Operate the transmitter only with the accompanying carrying belt.
1.1.6.
Protective Features
The machine functions can be stopped either by: 1.
Pushing the emergency stop button on the transmitter control panel (EMERGENCY STOP!).
2.
Turning the transmitter key switch to the 'off' position (machine function will stop approximately 0.5 seconds (450 ms) after the switch is turned to the 'off' position).
Additional safety features include the protective guard around the upper section of the transmitter housing. This guard helps to protect against accidental activation of controls and unintentional operation. These safety features are included for the operator’s as well as other person’s protection within the work area.
WARNING!
1.1.7.
Safety features must not be removed or modified in any way.
Reaction in Emergency Situations
1.
If there is an emergency, press immediately the red emergency stop (EMERGENCY STOP!) push - button (see picture).
2.
After the emergency stop push - button has been pressed, follow carefully the instructions in the machine's operating manual.
Type GL
Type Nova 6
EMERGENCY – STOP – PUSH - BUTTON
2. Operating Instructions WARNING!
Operators are strictly forbidden to use the radio remote control unit unless they have carefully read and fully understood this operating manual. Special attention must be given to the safety instructions in this manual!
2.1. Battery Handling Each HETRONIC radio remote control system will be delivered with two fully charged batteries. One of them will be inserted into the battery compartment located on the bottom of the transmitter. The operating time of one charged battery is approximately 8 hours.
2.1.1. Inserting the Battery Ensure that the battery compartment is completely clean, as dirt might cause contact problems. Insert the battery with both guide pins in the corresponding guide bars of the battery compartment. Now press the battery on the marked spot until it latches into its compartment. Type Nova: Insert the battery with both guide bars on the lower side of the battery in the corresponding guide slots of the battery compartment. Now press the battery until it latches into its compartment.
Type GL
Type Nova
2.1.2.
Changing the Battery
The battery voltage will be controlled continuously by the transmitter’s electronic. An acoustic interval signal will be heard in the transmitter when the capacity of the transmitter battery is nearly exhausted. When the signal is heard the following steps must be immediately taken: -
Position the machine into a safe place or safe condition within 30 seconds after hearing the signal.
WARNING! -
The transmitter will switch to the Emergency Stop condition after 30 seconds!
Switch the transmitter 'off' by turning the key switch to the '0' position. Remove the discharged battery by pushing it slightly forward and lifting it up and out of the battery compartment. Insert a fully charged battery. Continue like described in point 2.2.2.'starting the radio remote control'. The radio remote control is again ready for operation.
Battery – type GL
Battery – type Nova
2.1.3.
Charging the Battery
WARNING!
Danger of Explosion! Use only HETRONIC original parts. If no original HETRONIC parts are used there could be a danger of explosion! An explosion may result in the release of harmful gases or fumes and / or flying debris. This may result in injury or death of the operator or others present within the work area.
Your HETRONIC radio remote control system will be delivered with fully charged batteries, that means your radio remote control system is immediately ready for operation. Battery Charging Instructions: Type GL: Insert the battery with both guide pins in the corresponding guide bars in the battery compartment of the battery charger. Type Nova: Place the battery with both guide bars on the lower side of the battery in the corresponding grooves of the battery charger’s battery compartment. Now press the battery on the marked spot until it latches into its compartment. The green LED on the charger stays lit during the charging process. When the battery is fully charged, the LED starts flashing. Insert the second battery into the battery charger to ensure that there is always a fully charged battery available.
2.1.4.
The Battery Charger
The battery charger operates with an operating voltage of 12 VDC / 24 VDC. A green LED indicates the beginning of the charging process. After a charging time of approximately 3,5 hours (type Nova), 6 hours (type GL) the flashing green LED indicates that the charging process is finished. The charger recognises automatically when the battery is fully charged. When it is fully charged, the charger switches to a 'trickle' charging condition. It does not matter whether the battery is discharged or partially charged, as the battery charger automatically regulates the charging process. To reach a long operating time of the batteries, you should charge the battery only when an acoustic interval signal is heard from the transmitter, which indicates that the capacity of the transmitter is nearly exhausted.
IMPORTANT!
Rechargeable accumulators are hazardous waste! Contact an expert company for the waste disposal and exploitation. Defective accumulators can be disposed by HETRONIC.
2.1.5.
Indication for the Battery Charger’s Installation
The charging unit should be installed in the vehicle and connected directly to the battery via a fuse. This means that it should also be operational when the ignition is switched off. The charging unit’s current consumption is so slight that effects on the vehicle’s battery are minimal. The system is protected against polarity reversal. Ensure that the charging unit will be operated on dry places only.
2.2. To Begin Operation The safety check as described in the following paragraphs 2.2.1. and 2.2.2. has to be completed before the radio remote control system is activated. The safety check must be performed at least once a day, before the start of any operation and at all shift changes.
IMPORTANT! A transmitter drawing is enclosed to this operating manual. Transmitter layout and inscription vary according to the customer’s requests. In most cases, however, they are identical to the inscription of the present control. The only difference is that the machine is controlled without a cable control. Consult the machine manufacturer’s manual and the transmitter drawing additional to inform about the arrangement of the transmitter’s operating elements and their corresponding functions. The following description refers to the control elements and peculiarities of the radio remote control.
WARNING!
2.2.1.
Danger to personnel and property! The operator must read and fully understand the emergency stop function outlined in the machine manufacturer's operating manual before beginning any operation! Test the EMERGENCY STOP function as described in the machine manufacturer's operating manual before beginning any operation!
Optical Check-up
Always check the transmitter for any physical damages before any operation. -
Do all safety features exist and are they in a good condition? No broken parts anywhere? All rubber cuffs and push button caps without rips?
Never operate a transmitter which has such damages! Eliminate the faults immediately!
2.2.2.
Safety Check-Up and Starting the Radio Remote Control
Check list for the first start of operation (this checklist must be carefully followed before beginning any operation!) -
-
-
-
WARNING!
Keyswitch on the transmitter in position '0' (off), emergency stop push - button in position '0' (off), (pull it out – type GL), (turn it right – type Nova). Insert a charged battery into the battery compartment located on the bottom of the transmitter (see section 2.1.1.). Switch the transmitter on by turning the keyswitch to the position 'I' (on) and a short acoustic signal will be heard. Wait for the second acoustic signal (approx. 3 seconds). The LED on the transmitters control panel will begin to flash. Now push the green push button “S1” on the transmitter. Check the deflection of the control elements. Do the machine functions correspond with the transmitter functions? Now check the EMERGENCY STOP function as described in the machine manufacturer’s manual. However use the EMERGENCY STOP push - button on the transmitter instead of the EMERGENCY STOP switch on the machine. Push the EMERGENCY STOP now. Make sure that no function can be controlled after pushing the EMERGENCY STOP push - button. Is the safety check successful and the EMERGENCY STOP function operates perfectly? Pull out the EMERGENCY STOP push - button. Push the green push - button 'S1' (start) on the transmitter. Both the radio remote control and the machine are now ready for operation.
Switch the machine 'off' immediately should there be a fault or any problems with the safety check. Inform your dealer at once to repair the system. Never operate a machine when the EMERGENCY STOP function does not operate properly. Danger to personnel and property by non - observance of this regulation. All measures which do not confirm with this regulation can lead to the loss of the operating permission and your warranty.
Starter – Push – Button “S1” Type GL
Type Nova
2.3. Speed Control The Radio Remote Control System BMS is equipped with a twofold speed control. It is possible to select a speed range via a switch. You can choose between a maximum adjustable power with switch position “rabbit” and a lower one with